30 day money back guarantee
Robust retroreflective sensor for complex applications, small design, polarization filter, 9 m detection range, red light, light/dark on, PNP output, stability alarm output, M12 plug
| Effective detection range | 0 ... 6.5 m | |||||||
| Reflector distance | 0.01 ... 6.5 m | |||||||
| Threshold detection range | 9 m |
|||||||
| Reference target | H85-2 reflector | |||||||
| Light source | LED | |||||||
| Light type | modulated visible red light , 660 nm | |||||||
| Polarization filter | yes | |||||||
| Diameter of the light spot | approx. 170 mm at detection range 6.5 m | |||||||
| Opening angle | 1.5 ° | |||||||
| Ambient light limit | ||||||||
| ||||||||
MTTFd    1000 a
Mission Time (TM)Â Â Â Â 20 a
Diagnostic Coverage (DC)Â Â Â Â 0 %
Operation indicator    LED green, flashes in case of short-circuit
Function indicator    2 LEDs yellow, light up when light beam is free, flash when falling short of the operating reserve, are off when light beam is interrupted
Control elements    rotary switch for light/dark, sensitivity adjuster
Mission Time (TM)Â Â Â Â 20 a
Diagnostic Coverage (DC)Â Â Â Â 0 %
Operation indicator    LED green, flashes in case of short-circuit
Function indicator    2 LEDs yellow, light up when light beam is free, flash when falling short of the operating reserve, are off when light beam is interrupted
Control elements    rotary switch for light/dark, sensitivity adjuster
Operating voltage  UB  10 ... 30 V DC
Ripple    max. 10 %
No-load supply current  I0  max. 40 mA
Stability alarm output    1 PNP, inactive when level falls below operating reserve after approx. 5 s.
Immediately inactive if the beam is interrupted 4 times during the flashtime.
Switching type    light/dark on switchable
Signal output    1 PNP output, short-circuit protected, reverse polarity protected, open collector
Switching voltage    max. 30 V DC
Switching current    max. 0.2 A
Voltage drop  Ud  ≤ 2.5 V DC
Switching frequency  f  1000 Hz
Response time    0.5 ms
Ripple    max. 10 %
No-load supply current  I0  max. 40 mA
Stability alarm output    1 PNP, inactive when level falls below operating reserve after approx. 5 s.
Immediately inactive if the beam is interrupted 4 times during the flashtime.
Switching type    light/dark on switchable
Signal output    1 PNP output, short-circuit protected, reverse polarity protected, open collector
Switching voltage    max. 30 V DC
Switching current    max. 0.2 A
Voltage drop  Ud  ≤ 2.5 V DC
Switching frequency  f  1000 Hz
Response time    0.5 ms
| Product standard | EN 60947-5-2 |
| Standard conformity | ||||||||
| ||||||||
| Protection class | II, rated voltage ≤ 300 V AC with pollution degree 1-2 according to IEC 60664-1 | |
| UL approval | cULus | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
|
Ambient temperature |
-40 ... 60 °C (-40 ... 140 °F) | |
| Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
| Degree of protection | IP67 | ||||||||||
| Connection | Metal connector, M12, 5-pin, 90° rotatable | ||||||||||
| Material | |||||||||||
| |||||||||||
| Mass | 60 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||