interfaces
number of electrical/optical connections / for network
components or terminal equipment / maximum
2
number of optical interfaces / for network components or
terminal equipment / maximum
2
number of 1000 Mbit/s SC ports (LX) 2
design of the optical interface / for network components or
terminal equipment
SC
wavelength / of the optical interface 1310 nm; Single-mode
connectable optical power relative to 1 mW
â—Ź of the transmitter output / minimum -9.5 dB
â—Ź of the transmitter output / maximum -3 dB
â—Ź of the receiver input / maximum -3 dB
optical sensitivity relating to 1 mW / of the receiver input /
minimum
-21 dB
attenuation factor / of the FOC transmission link / minimum
necessary
0 dB
range / at the optical interface / depending on the optical fiber
used
0 ... 10 km
ambient conditions
ambient temperature
● during operation -40 ... +70 °C
● during storage -40 ... +85 °C
● during transport -40 ... +85 °C
relative humidity / at 25 °C / without condensation / during
operation / maximum
95 %
protection class IP IP20
design, dimensions and weights
design Media module
width 60 mm
height 22 mm
depth 100 mm
net weight 0.08 kg
fastening method latched
â—Ź installation in media module slot Yes
standards, specifications, approvals
standard
â—Ź for FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2, Group IIC,
T4
â—Ź for hazardous zone EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX
0145 X
â—Ź for safety / from CSA and UL UL 60950-1, CSA C22.2 No. 60950-1