Technical data:
| Sensor principle | Electro-mechanical |
| Locking principle | Power to release |
| Positive action N/C solenoid monitoring contacts | 2 |
| N/O solenoid monitoring contacts | 0 |
| Positive action N/C door monitoring contacts | 2 |
| N/O door monitoring contacts | 0 |
| N/C contact for door monitoring | 0 |
| Locking force Fmax | 1,300 N (EN ISO 14119) |
| Locking force FZh | 1,000 N (EN ISO 14119) |
| Actuation force | ≥ 10 N |
| Retaining force | ≤ 20 N |
| Actuation frequency | ≤ 1,200 /h |
| Actuation directions | 4 |
| Approach speed | ≤ 20 m/min |