Rosemount 3051T Pressure Transmitter Flowmeter Sensor Kit w/ 1199 Flange3051TG3A2B21AK5M5T1P2Q4Q8S1HR5 + 1199WDA95AFFWG1DA00
New, sealed in box!
This product is shipped same-day and includes free overnight shipping!
3051T G 3 A 2B 2 1 A K5 M5 T1 P2 Q4 Q8 S1 HR5
Model:
Code - 3051T In-Line Pressure Transmitter
Pressure Type:
Code: G (gage)
Pressure range:
Code: 3 (-14.7 to 800 PSI)
Transmitter Output:
Code: A (4-20 mA with digital signal based on HART protocol)
Process Connection Style:
Code: 2B (1/2-14 NPT female [range 0-5 only])
Isolating diaphragm:
Code: 2 (316L stainless steel)
Sensor fill fluid:
Code: 1 (silicone)
Housing material:
Code: A (aluminum, 1/2-14NPT conduit entry size)
Code: A (aluminum, 1/2-14NPT conduit entry size)
Product Certifications:
Code: K5 (Dust ignition proof, intrinsically safe, and division 2)
Display and interface:
Code: M5 (LCD Display)
Transient Protection:
Code: T1 (transient protection termination block)
Cleaning Process Area:
Code: P2 (cleaning for special service)
Code: P2 (cleaning for special service)
Calibration Certification:
Code: Q4 (calibration certificate)
Material traceability certification
Code: Q8 (material traceability certification per EN 10204 3.1.B)
Diaphragm Assembly
Code: S1 (assemble to one Rosemount seal)
Code: S1 (assemble to one Rosemount seal)
Cannot find indication for code "HR5."
Flange Specifications:
1199WDA95AFFWG1DA00
1199-W-D-A-95-A-FFW-G-1-D-A-00
Connection Type:
Code: W (welded-repairable, 1 or 2 seal system (high side)
Fill Fluid
Code: D - Silicone 200
SST Armored Capillary
Code: A - unable to find code indication
Distance to Process
Code: 95 - unable to find code indication
Industry Standard
Code: A - ANSI/ASME B16.5
Process connection style
Code: FFW Flush flanged seal
Process Connection Size
Code: G - 2in
Diaphragm & Wetted Material
Code: A - 316L SST
Flange Material
Code: D - 316 SST
Flange Pressure Rating
Code: 1 - Class 150