New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A
New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A

New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A

Regular price $299.99 Save $-299.99
/

Only 2 items in stock!

New Volta AMHs 2-80U+ Double Thermostat 10..55*C / -5..75*C 230V IP54 2A

60/60003304
F-NR 019138840101407

New product without original packaging.

Fast US Shipping

30-day guarantee.

The AMHs 2-80U + surface concentration thermostat consists of two separate measuring and switching systems in one thermostat housing. It works as a safety temperature limiter STL with manual reset and as a temperature monitor TM with automatic restart after hysteresis. In this way, the AMHs 2-80U + "monitors" the set temperature, switches the device off when the set temperature is exceeded and it switches on automatically again after it has gone through a hysteresis. The AMHs 2-80U + is TÜV tested without to DIN EN 14597 and encapsulated according to IP54. The temperature range of the TM is + 10 ° C to + 55 ° C that of the STL is fixed at 75 ° C.

Technical description

Function

The surface background thermostat works on the principle of liquid expansion. If the temperature changes in a liquid-filled sensor system - consisting of a sensor, capillary and membrane - the volume changes. The resulting stroke of the membrane actuates the microswitch by lifting. Only the temperature sensor is used to record the temperature.

Switching function (STL and TM)

If the Temperature at the Temperature Sensors exceed the set limit, The Sensor Dipe of the Microswitch is relieved and the circuit is open.

TM with automatic restart

If the value falls below the set limit (by the hysteresis), the Microsoft is returned automatically to the starting position.

STL with mechanical lock and restart lock

When the set limit is exceeded, the circuit open is and the microswitch is locked is mechanically. After falling below the limit by approx. 10% of the temperature range, the microswitch can be unlocked by the cap nut acknowledgement by the pressing button.

Switching element

Encapsulated microswitch with single-pole changeover contact and restart lock (opens when the temperature rises) at STL. The TM has an encapsulated microswitch with a single-pole changeover contact.

Self-monitoring

The unbreakable thermostat (STL), with enhanced safety according to DIN EN 14579, opens the circuit when the measuring system is destroyed and remains mechanically locked in this position.