New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ
New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ

New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ

Regular price $1,299.99 Save $-1,299.99
/

Only 11 items in stock!

New Schneider Foxboro FBM202 2 Channel Isolated 8 Input, Thermocouple/mV RH926EQ

New product from OEM packaging.

Fast 1-Day US Shipping

30-day Warranty.


The FBM202 Thermocouple/mV Input contains eight thermocouple input channels, and one isolated RTD reference junction compensation channel (for terminal temperature sensing). Each thermocouple/mV channel accepts standard thermocouples for various temperature ranges, and each provides thermocouple burnout detection (up-scale). The inputs are galvanically isolated from other channels and ground.
The module performs the signal conversion required to interface the electrical input signals from the field sensors to the optionally redundant Fieldbus. It executes an Analog Input application program, which provides integration time and Rate of Change Limits
configurable options.

Input Channels

Eight isolated and independent thermocouple/mV input channels. One isolated reference junction temperature compensation channel.

Input Range

–10.5 to +69.5 mV dc (–10.5 to +69.5 mV dc equals 0 to 64000 raw counts. Input of 71.419 mV equals 65535 raw counts (full range of module))

Reference Junction

Reference junction temperature compensation is provided by a 4-wire 100 ohm platinum RTD (IEC 751, Class B) at the termination assembly.

Accuracy

MILLIVOLT INPUT : ±0.03% of span (±24 µV) at 25°C

RTD CHANNEL : ±0.03% of span

RTD REFERENCE JUNCTION CONFORMITY : ±0.25°C

THERMOCOUPLE CONFORMITY : ±0.25°C

ACCURACY TEMPERATURE COEFFICIENT : ±50 ppm/°C

RTD REFERENCE JUNCTION MEASUREMENT ACCURACY : ±0.50°C (When using the RTD internal to the Foxboro supplied termination assemblies)

DIFFERENTIAL INPUT IMPEDANCE : 10 MΩ

COMMON MODE VOLTAGE : Up to 30 V ac or 60 V dc

Integration Period

Software configurable

Input Open Circuit Voltage

250 mV dc through 10 M ohms (mV channels)

Input Signal A/D Conversion

Each channel performs A/D signal conversion using an independent Sigma-Delta converter.

Typical Thermocouple Types

B, E, J, K, N, R, S, T and other millivolt signals

Thermocouple Burnout Detection

Full upscale value

Input Channel Isolation

Each channel is galvanically isolated from all other channels and earth (ground). The module withstands, without damage, a potential of 600 V ac applied for one minute between any channel and ground, or between a given channel and any other channel.

CAUTION

This does not imply that these channels are intended for permanent connection to

hazardous voltage circuits. Connection of these channels to voltages greater than

30 V ac or 60 V dc violates electrical safety code requirements and may expose users to

electric shock.

Communication

Communicates with its associated FCM or FCP via the redundant 2Mbps module Fieldbus.

Power Requirements

INPUT VOLTAGE RANGE (REDUNDANT) : 24 V dc, +5%, -10%

CONSUMPTION : 3 W (maximum)

HEAT DISSIPATION : 3 W (maximum)

Calibration Requirements

Calibration of the module and termination assembly is not required.

Industrial Immunity Levels

RoHS COMPLIANCE

Complies with European RoHS Directive

2011/65/EU