New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00
New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00

New Rosemount Emerson Sensor 3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00

Regular price $4,499.99 Save $-4,499.99
/

Only 2 items in stock!
New Rosemount 3051T Pressure Transmitter Flowmeter Sensor Kit w/ 1199 Flange
3051TG2A2B21AK5M5P2Q4Q8S1HR5 + 1199WDA95AFFWG2DA00

Box has some exterior damage, product is new and sealed in the box. 30 day money back guarantee.
This item ships same day and includes free overnight shipping!

3051TG2A2B21AK5M5P2Q4Q8S1HR5 
3051T-G-2-A-2B-2-1-A-K5-M5-P2-Q4-Q8-S1-HR5

Model:
Code - 3051T In-Line Pressure Transmitter

Pressure Type:
Code: G (gage)
Pressure range: 
Code: 2 (-14.7 to 150 PSI)

Transmitter Output:
Code: A (4-20 mA with digital signal based on HART protocol)

Process Connection Style:
Code: 2B (1/2-14 NPT female [range 0-5 only])

Isolating diaphragm:
Code: 2 (316L stainless steel)

Sensor fill fluid: 
 Code: 1 (silicone)

Housing material: 
Code: A (aluminum, 1/2-14NPT conduit entry size)

Product Certifications: 
Code: K5 (Dust ignition proof, intrinsically safe, and division 2)
Display and interface:
Code: M5 (LCD Display)

Cleaning Process Area: 
Code: P2 (cleaning for special service)

Calibration Certification:
Code: Q4 (calibration certificate)

Material traceability certification:
Code: Q8 (material traceability certification per EN 10204 3.1.B)

Diaphragm Assembly:
Code: S1 (assemble to one Rosemount seal)

Unable to find indication for code HR5.



Flange Specifications: 

1199WDA95AFFWG2DA00
1199-W-D-A-95-A-FFW-G-2-D-A-00
Connection Type:
CodeW (welded-repairable, 1 or 2 seal system (high side)

Fill Fluid
CodeD - Silicone 200

Industry Standard
CodeA - ANSI/ASME B16.5

Process connection style
Code: FFW Flush flanged seal 
Flange Pressure Rating
CodeG - 2in