Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD
Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD

Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD

Regular price $399.99 Save $-399.99
/

Only 1 items in stock!
Factory seal + Full product code + 30 Day money back guarantee + Free shipping= Low risk for you

Honeywell 00705-A-1735 Sensor 705 High Temp RTG 3/4 UL for Sensepoint XCD RFD

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
    • Gas Detection Sensors & Transmitters
  • Alarm Settings
    • 5% LEL
  • Features & Benefits
    • Cost Effective
    • Excellent Performance
    • Flexibility
    • Reliable Operation
    • Robust Construction
  • Repeatability
    • Better than ±2% LEL

Standards & Certifications

  • NEMA Rating
    • NEMA 4X

Electrical Specifications

  • Power Consumption
    • 0.7W @200 mA

Material Specifications

  • Enclosure Material
    • Aluminum

Others

  • Industry
    • Energy


Technical Specifications

  • Humidity Range
    • Continuous: 20 to 90% RH
    • Intermittent: 10 to 99% RH
  • Accuracy
    • 0-100% LEL
  • Maximum Pressure
    • 110 kPa
  • Gas Type
    • Flammable
  • Warm Up Time
    • 30 min
  • Stability (zero)
    • With Humidity: < ±3% LEL
    • With Pressure: < ±3% LEL
    • With Temperature: < ±3% LEL
    • With Time: < ±5% LEL/yr
  • Stability (span)
    • With Humidity: < ±3% LEL
    • With Pressure: < ±3% LEL
    • With Temperature: < ±4% LEL
    • With Time: < ±5% LEL/yr
  • Speed of Response
    • T60 < 6 sec
    • T90 < 10 sec
  • Signal Output
    • mV Bridge
  • Mounting Thread
    • 3/4 in NPT
  • Measuring Range
    • 0-20% LEL, 0-100% LEL (Control Card Dependent)