Only includes what's pictured in photos.
30 day money back guarantee.
T15 Explosion proof RTD thermometer, US style
Full P/N: T15-E8A5M5BKA1
-
Measuring principle
Resistance Temperature Detector
-
Characteristic / Application
Explosion Proof US style
modular temperature assembly
for heavy duty applications
with extension
to be used with existing thermowell -
Thermowell / protection tube
to be used with thermowell
-
Insert / probe
mineral insulated (MI), flexible
PTFE-insulated, rigid -
Outer diameter protection tube / Insert
Not applicable
-
Max. immersion length on request
up to 100" (2540 mm)
others on request -
Material protection tube/ thermowell
Sensor sheath
316/316L -
Optional coating
Not defined
-
Process connection
male thread:
NPT1/2" -
Tip shape
straight
-
Surface roughness Ra
Not defined
-
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F) -
Max. process pressure (static)
Not applicable
-
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751 -
Response time
63% rt 3 s
-
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
-
Ex - approvals
FM XP DIP
FM XP NI DIP
CSA XP DIP
CSA XP NI DIP
FM/CSA XP DIP
FM/CSA XP NI DIP
CSA C/US XP, DIP
cCSAus General Purpose -
Certification
SIL (transmitter only)
Approval: |
E |
|||
Immersion Length XA: |
8 |
|||
Sheath Diameter: |
A |
|||
Extension: |
5 |
|||
Sensor Type: |
M |
|||
Enclosure; Cable Entry: |
5 |
|||
Electrical Connection: |
B |
|||
Version: |
K |
|||
Additional Option 1: |
A |
|||
Additional Option 2: |
1 |