{"product_id":"siemens-sirius-3rh1131-1bb40-auxilliury-contactor-relay-6a-230v-31e-3no-1nc","title":"Siemens Sirius 3RH1131-1BB40 Auxilliury Contactor Relay 6A 230V 31E 3NO + 1NC","description":"New in box. 30 day money back guarantee. \u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003eManufacturer specs: \u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eGeneral technical data\u003c\/div\u003e\n\u003cdiv\u003eSize of contactor S00\u003c\/div\u003e\n\u003cdiv\u003eProduct extension\u003c\/div\u003e\n\u003cdiv\u003e● Auxiliary switch Yes\u003c\/div\u003e\n\u003cdiv\u003eInsulation voltage\u003c\/div\u003e\n\u003cdiv\u003e● with degree of pollution 3 rated value 690 V\u003c\/div\u003e\n\u003cdiv\u003eDegree of pollution 3\u003c\/div\u003e\n\u003cdiv\u003eSurge voltage resistance rated value 6 kV\u003c\/div\u003e\n\u003cdiv\u003eProtection class IP\u003c\/div\u003e\n\u003cdiv\u003e● on the front IP20\u003c\/div\u003e\n\u003cdiv\u003eMechanical service life (switching cycles)\u003c\/div\u003e\n\u003cdiv\u003e● of contactor typical 30 000 000\u003c\/div\u003e\n\u003cdiv\u003e● of the contactor with added electronicscompatible auxiliary switch block typical\u003c\/div\u003e\n\u003cdiv\u003e5 000 000\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eEquipment marking\u003c\/div\u003e\n\u003cdiv\u003e● acc. to DIN EN 61346-2 K\u003c\/div\u003e\n\u003cdiv\u003e● acc. to DIN EN 81346-2 K\u003c\/div\u003e\n\u003cdiv\u003eAmbient conditions\u003c\/div\u003e\n\u003cdiv\u003eAmbient temperature\u003c\/div\u003e\n\u003cdiv\u003e● during operation -25 ... +60 °C\u003c\/div\u003e\n\u003cdiv\u003e● during storage -55 ... +80 °C\u003c\/div\u003e\n\u003cdiv\u003e● during transport -55 ... +80 °C\u003c\/div\u003e\n\u003cdiv\u003eControl circuit\/ Control\u003c\/div\u003e\n\u003cdiv\u003eType of voltage of the control supply voltage DC\u003c\/div\u003e\n\u003cdiv\u003eControl supply voltage at DC\u003c\/div\u003e\n\u003cdiv\u003e● rated value 24 V\u003c\/div\u003e\n\u003cdiv\u003eClosing power of magnet coil at DC 3.2 W\u003c\/div\u003e\n\u003cdiv\u003eHolding power of magnet coil at DC 3.2 W\u003c\/div\u003e\n\u003cdiv\u003eAuxiliary circuit\u003c\/div\u003e\n\u003cdiv\u003eNumber of NC contacts\u003c\/div\u003e\n\u003cdiv\u003e● for auxiliary contacts 1\u003c\/div\u003e\n\u003cdiv\u003e— instantaneous contact 1\u003c\/div\u003e\n\u003cdiv\u003e— delayed switching 0\u003c\/div\u003e\n\u003cdiv\u003e— lagging switching 0\u003c\/div\u003e\n\u003cdiv\u003e— make-before-break switching 0\u003c\/div\u003e\n\u003cdiv\u003eNumber of NO contacts\u003c\/div\u003e\n\u003cdiv\u003e● for auxiliary contacts 3\u003c\/div\u003e\n\u003cdiv\u003e— instantaneous contact 3\u003c\/div\u003e\n\u003cdiv\u003e— delayed switching 0\u003c\/div\u003e\n\u003cdiv\u003e— leading contact 0\u003c\/div\u003e\n\u003cdiv\u003e— make-before-break switching 0\u003c\/div\u003e\n\u003cdiv\u003eNumber of CO contacts\u003c\/div\u003e\n\u003cdiv\u003e● for auxiliary contacts 0\u003c\/div\u003e\n\u003cdiv\u003e● of auxiliary contacts instantaneous contact 0\u003c\/div\u003e\n\u003cdiv\u003eIdentification number and letter for switching\u003c\/div\u003e\n\u003cdiv\u003eelements\u003c\/div\u003e\n\u003cdiv\u003e31 E\u003c\/div\u003e\n\u003cdiv\u003eOperating current at AC-12 maximum 10 A\u003c\/div\u003e\n\u003cdiv\u003eOperating current at AC-15\u003c\/div\u003e\n\u003cdiv\u003e● at 230 V rated value 6 A\u003c\/div\u003e\n\u003cdiv\u003e● at 400 V rated value 3 A\u003c\/div\u003e\n\u003cdiv\u003e● at 500 V rated value 2 A\u003c\/div\u003e\n\u003cdiv\u003e● at 690 V rated value 1 A\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003e● at 24 V rated value 10 A\u003c\/div\u003e\n\u003cdiv\u003e● at 110 V rated value 3 A\u003c\/div\u003e\n\u003cdiv\u003e● at 220 V rated value 1 A\u003c\/div\u003e\n\u003cdiv\u003eOperating current at 1 current path at DC-13\u003c\/div\u003e\n\u003cdiv\u003e● at 24 V rated value 10 A\u003c\/div\u003e\n\u003cdiv\u003e● at 110 V rated value 1 A\u003c\/div\u003e\n\u003cdiv\u003e● at 220 V rated value 0.27 A\u003c\/div\u003e\n\u003cdiv\u003eContact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA)\u003c\/div\u003e\n\u003cdiv\u003eShort-circuit protection\u003c\/div\u003e\n\u003cdiv\u003eDesign of the fuse link\u003c\/div\u003e\n\u003cdiv\u003e● for short-circuit protection of the auxiliary switch\u003c\/div\u003e\n\u003cdiv\u003erequired\u003c\/div\u003e\n\u003cdiv\u003efuse gL\/gG: 10 A\u003c\/div\u003e\n\u003cdiv\u003eInstallation\/ mounting\/ dimensions\u003c\/div\u003e\n\u003cdiv\u003eMounting position +\/-180° rotation possible on vertical mounting surface; can be\u003c\/div\u003e\n\u003cdiv\u003etilted forward and backward by +\/- 22.5° on vertical mounting\u003c\/div\u003e\n\u003cdiv\u003esurface\u003c\/div\u003e\n\u003cdiv\u003eMounting type screw and snap-on mounting\u003c\/div\u003e\n\u003cdiv\u003eHeight 57.5 mm\u003c\/div\u003e\n\u003cdiv\u003eWidth 45 mm\u003c\/div\u003e\n\u003cdiv\u003eDepth 72 mm\u003c\/div\u003e\n\u003cdiv\u003eRequired spacing\u003c\/div\u003e\n\u003cdiv\u003e● with side-by-side mounting\u003c\/div\u003e\n\u003cdiv\u003e— at the side 0 mm\u003c\/div\u003e\n\u003cdiv\u003eConnections\/Terminals\u003c\/div\u003e\n\u003cdiv\u003eType of electrical connection\u003c\/div\u003e\n\u003cdiv\u003e● for auxiliary and control current circuit screw-type terminals\u003c\/div\u003e\n\u003cdiv\u003eType of connectable conductor cross-sections\u003c\/div\u003e\n\u003cdiv\u003e● for auxiliary contacts\u003c\/div\u003e\n\u003cdiv\u003e— solid 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²\u003c\/div\u003e\n\u003cdiv\u003e— finely stranded with core end processing 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)\u003c\/div\u003e\n\u003cdiv\u003e● at AWG conductors for auxiliary contacts 2x (20 ... 16), 2x (18 ... 14), 1x 12\u003c\/div\u003e\n\u003cdiv\u003eSafety related data\u003c\/div\u003e\n\u003cdiv\u003eB10 value\u003c\/div\u003e\n\u003cdiv\u003e● with high demand rate acc. to SN 31920 1 000 000; With 0.3 x Ie\u003c\/div\u003e\n\u003cdiv\u003eProportion of dangerous failures\u003c\/div\u003e\n\u003cdiv\u003e● with low demand rate acc. to SN 31920 40 %\u003c\/div\u003e\n\u003cdiv\u003e● with high demand rate acc. to SN 31920 75 %\u003c\/div\u003e\n\u003cdiv\u003eT1 value for proof test interval or service life acc. to\u003c\/div\u003e\n\u003cdiv\u003eIEC 61508\u003c\/div\u003e\n\u003cdiv\u003e20 y\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Blackstar Assets","offers":[{"title":"Default Title","offer_id":46755033874581,"sku":"AMP IND-39545-2643 CR-132 TUB FOIRGNEAMH","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1353\/6489\/files\/116799604467-0.jpg?v=1765838821","url":"https:\/\/www.blackstarassets.com\/products\/siemens-sirius-3rh1131-1bb40-auxilliury-contactor-relay-6a-230v-31e-3no-1nc","provider":"Blackstar Assets","version":"1.0","type":"link"}