{"product_id":"schmidt-flow-sensor-ss-20-500-521501-41121-3m-cable-1m-s-range-pu-coat-10-bar","title":"Schmidt Flow Sensor SS 20.500 521501-41121 3m Cable, 1m\/s Range, PU Coat, 10 bar","description":"\u003cdiv\u003e\u003cstrong\u003e1 SENSOR PER ORDER\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\u003c\/div\u003e\u003cdiv\u003e\u003ci\u003eUnused product + Full product code + 30 Day money back guarantee + Free shipping= Low risk for you=\u003c\/i\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eSchmidt Flow Sensor SS 20.500 521501-41121 3m Cable, 1m\/s Range, PU Coat, 10 bar\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003eRemote sensor with 3 m cable\u003cbr\u003eMeasuring range 0 … 1 m\/s\u003cbr\u003eStandard adjustment [calibration]\u003cbr\u003eWith protective coating polyurethane derivate black (sensor head only)\u003c\/div\u003e\u003cdiv\u003eMeasuring quantity    Standard flow velocity wN based on standard conditions 1)\u003cbr\u003eTemperature of medium TM\u003cbr\u003eMeasured medium    Air or nitrogen, other gases on request\u003cbr\u003eLower detection limit wN    0.06 m\/s\u003cbr\u003eMeasuring range TM    -40 … +85 °C\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ctable class=\"technisch_daten\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003eMeasuring accuracy\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eStandard w\u003csub\u003eN\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e±(3 % of measured value + [0.4 % of fmr; min. 0.02 m\/s]) \u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eHigh precision (optional) w\u003csub\u003eN\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e±(1 % of measured value + [0.4 % of fmr; min. 0.02 m\/s]) \u003csup\u003e2)\u003c\/sup\u003e (only for measuring range 0 … 1 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eResponse time (t\u003csub\u003e90\u003c\/sub\u003e) w\u003csub\u003eN\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e3 s (jump from 0 to 5 m\/s in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eTemperature gradient w\u003csub\u003eN\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e≤ 2 K\/min (at w\u003csub\u003eN\u003c\/sub\u003e 5 m\/s in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eT\u003csub\u003eM\u003c\/sub\u003e (w\u003csub\u003eN\u003c\/sub\u003e \u0026gt; 1 m\/s)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e±1 K (10 … 30 °C); ±2 K (remaining measuring range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003ctable class=\"technisch_daten\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003eOperating temperature\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eSensor probe\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e-40 … +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eElectronics\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e-20 … +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eStorage temperature\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e-40 … +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003ctable class=\"technisch_daten\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth colspan=\"2\"\u003eMaterial\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eAluminium, anodised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eSensor tube\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eStainless steel 1.4404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eSensor head\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003ePBT (glass-fibre reinforced), stainless steel 1.4404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eProtective coating (optional)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003ePolyurethane derivate (black, sensor head only) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eProtective sleeve (ATEX option)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eAluminium, anodised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eSensor cable (of remote sensor)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e(TPE, halogenfree, black)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\u003cdiv\u003e\n\u003ctable class=\"technisch_daten\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eHumidity\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eMeasuring mode: Non-condensing (\u0026lt; 95 % RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eOperating pressure (max.)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eCompact version: 10 bar (overpressure)\u003cbr\u003eRemote version: Atmospheric (700 hPa … 1,300 hPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eDisplay\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e4 x Duo-LEDs (green\/red\/orange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eSupply voltage\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e24 V AC\/DC ± 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eTyp. \u0026lt; 60 mA (max. 170 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eAnalog outputs\u003cbr\u003e Type: Auto U \/ I)\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003ew\u003csub\u003eN\u003c\/sub\u003e, T\u003csub\u003eM\u003c\/sub\u003e\u003cbr\u003e0 … 10 V \/ 4 … 20 mA (switching of signal characteristic depends on R\u003csub\u003eL\u003c\/sub\u003e)\u003cbr\u003e -Voltage output (0 … 10 V): R\u003csub\u003eL\u003c\/sub\u003e ≥ 550 Ω (short-circuit protected)\u003cbr\u003e - Current output (4 … 20 mA): R\u003csub\u003eL\u003c\/sub\u003e ≤ 500 Ω\u003cbr\u003e - Change-over hysteresis: 50 Ω\u003cbr\u003e - C\u003csub\u003eL\u003c\/sub\u003e ≤ 10 nF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003ePlug-in connector M12 (A-coded), male, 5-pin, screwed\u003cbr\u003eATEX approval only in combination with original cable!\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eMaximum cable length\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eVoltage interface \/ current interface: 100 m\u003cbr\u003eVoltage mode: Use AGND and R\u003csub\u003eL\u003c\/sub\u003e ≥ 10 k (mass offset)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eMounting position\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eArbitrary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eMinimum immersion depth\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e58 mm (\u0026lt; 58 mm on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eProtection type\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eSensor probe: IP67; enclosure: IP65; electrical connector: IP67 (with correctly attached cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eProtection class\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eIII (SELV or PELV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eATEX category\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003eGas (zone 2): II 3G Ex ec ic IIC T4 Gc\u003cbr\u003eDust (zone 22): II 3D Ex tc ic IIIC T135°C Dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"beschreibung\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"wert\"\u003e400 g max. (without connecting cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e","brand":"Blackstar Assets","offers":[{"title":"Default Title","offer_id":46755134996629,"sku":"AMP IND-39545-1168 LocTBD Tub Ersatz Bag1 #E309 -3","price":499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1353\/6489\/files\/116888420541-0.jpg?v=1765843423","url":"https:\/\/www.blackstarassets.com\/products\/schmidt-flow-sensor-ss-20-500-521501-41121-3m-cable-1m-s-range-pu-coat-10-bar","provider":"Blackstar Assets","version":"1.0","type":"link"}