{"product_id":"rosemount-3051t-pressure-transmitter-flowmeter-sensor-kit-w-1199-flange-nib","title":"Rosemount 3051T Pressure Transmitter Flowmeter Sensor Kit w\/ 1199 Flange, NIB","description":"\u003cdiv\u003e\u003cstrong\u003eRosemount 3051T Pressure Transmitter Flowmeter Sensor Kit w\/ 1199 Flange, NIB\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eMODEL: 3051TG3W2B21AK5M5P2Q4Q8S1 + 1199WDA95ARFW21DYA5J\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eNew open box. Flange \/ sensor is sealed (pictured) but box may have some minor shelf wear-and-tear. \u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003eThis product ships same day and includes free overnight delivery!\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003eRosemount 3031-60-0020 \/ AD\u003c\/div\u003e\u003cdiv\u003eFM APPROVED\u003c\/div\u003e\u003cdiv\u003eNEMA 4X \u003c\/div\u003e\u003cdiv\u003eAMBIENT TEMPERATURE LIMITS: -55F TO 185F\u003c\/div\u003e\u003cdiv\u003ePROOF FOR CLASS I DIV 1 GROUPS B C \u0026amp; D \u003c\/div\u003e\u003cdiv\u003eDUST IGNITION PROOF FOR CLASS II DIV 1 GROUPS E, F, G\u003c\/div\u003e\u003cdiv\u003eNONINCENDIVE CLASS I DIV 2 GROUPS A, B, C \u0026amp; D\u003c\/div\u003e\u003cdiv\u003eHART 4-20mA \/ LOW POWER\u003c\/div\u003e\u003cdiv\u003eTA +-50 TO 70 C\u003c\/div\u003e\u003cdiv\u003eFIELBUS \/ PROFIBUS TA -50 TO 60 C\u003c\/div\u003e\u003cdiv\u003eI.S. CL I, II, III, DIV 1\u003c\/div\u003e\u003cdiv\u003eHAZ LOC WHEN INSTALLED PER ROSEMOUNT DRAWING 03031-1019 TEMP CODE T4\u003c\/div\u003e\u003cdiv\u003eMAX W.P. 275 PSI \/ 19.0BAR\u003c\/div\u003e\u003cdiv\u003eSUPPLY 9-30 VDC \/ 17.5mA\u003c\/div\u003e\u003cdiv\u003eSERIAL: 2729290\u003c\/div\u003e\u003cdiv\u003eCAL: 0 TO 275   PSI \u003c\/div\u003e\u003cdiv\u003eMODEL: 3051TG3W2B21AK5M5P2Q4Q8S1 + 1199WDA95ARFW21DYA5J\u003c\/div\u003e\u003cdiv\u003esw: 2.5.0(1..1)\u003c\/div\u003e\u003cdiv\u003eID: 4444\u003c\/div\u003e\u003cdiv\u003eMFR 08 \/ 15\u003c\/div\u003e\u003cdiv\u003exxxxx-2102-3132 1\/2 Sil GP R3 sst\u003c\/div\u003e\u003cdiv\u003e12961357\u003c\/div\u003e\u003cdiv\u003e316L \/ T4K7\u003c\/div\u003e\u003cdiv\u003eU15J003517\u003c\/div\u003e\u003cdiv\u003eDP0001 1015 S6 1 150\u003c\/div\u003e\u003cdiv\u003eASTM A182GR 316 \/ 316L MH52\u003c\/div\u003e\u003cdiv\u003eIncludes 3058-0001 seal\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cfont size=\"5\"\u003eModel Components and specifications: \u003c\/font\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e3051TG3W2B21AK5M5P2Q4Q8S1 \u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\u003cdiv\u003e3051T - G - 3 - W - 2B - 2 -1 - A - K5 - M5 - P2 - Q4 - Q8 - S1\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode \u003c\/i\u003e- 3051T In-Line Pressure Transmitter\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003ePressure Type:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: G (gage)\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003ePressure range:\u003c\/strong\u003e \u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: 3 (-14.7 to 800 PSI)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eTransmitter Output:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: W (PROFIBUS PA Protocol)\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eProcess Connection Style:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: 2B (1\/2-14 NPT female [range 0-5 only])\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eIsolating diaphragm:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: 2 (316L stainless steel)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eSensor fill fluid: \u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: 1 (silicone)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003eHousing material: \u003c\/strong\u003e\u003cbr\u003e\u003ci\u003eCode\u003c\/i\u003e: A (aluminum, 1\/2-14NPT conduit entry size)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003eProduct Certifications: \u003c\/strong\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: K5 (Dust ignition proof, intrinsically safe, and division 2)\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eDisplay and interface:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: M5 (LCD Display)\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003eCleaning Process Area: \u003c\/strong\u003e\u003cbr\u003e\u003ci\u003eCode\u003c\/i\u003e: P2 (cleaning for special service)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eCalibration Certification:\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: Q4 (calibration certificate)\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eMaterial traceability certification\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003ci\u003eCode:\u003c\/i\u003e Q8 (material traceability certification per EN 10204 3.1.B)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003eDiaphragm Assembly \u003cbr\u003e\u003c\/strong\u003e\u003ci\u003eCode:\u003c\/i\u003e S1 (assemble to one Rosemount seal)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eFlange Specifications: \u003c\/strong\u003e1199WDA95ARFW21DYA5J\u003c\/div\u003e\n\u003cdiv\u003e(1199-W-D-A-95-A-RFW-2-1-D-Y-A-5-J)\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cb\u003eConnection Type:\u003c\/b\u003e\u003ci\u003e\u003cbr\u003e\u003c\/i\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e\u003cb\u003e: \u003c\/b\u003eW (welded-repairable, 1 or 2 seal system (high side)\u003cb\u003e\u003c\/b\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eFill Fluid\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e\u003cstrong\u003e: \u003c\/strong\u003eD - Silicone 200\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eSST Armored Capillary\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: A - unable to find code indication\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\u003cstrong\u003eDistance to Process\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: 95 - unable to find code indication\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eIndustry Standard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e\u003cstrong\u003e: \u003c\/strong\u003eA - ANSI\/ASME B16.5\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003eProcess connection style\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cdiv\u003e\n\u003ci\u003eCode\u003c\/i\u003e: RFW (flanged)\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e30 day money back guarantee. \u003c\/div\u003e","brand":"Blackstar Assets","offers":[{"title":"Default Title","offer_id":46754970599573,"sku":"AMP CRM IND-56185-109 #5 SHELF AP TOP RM 119-6","price":2999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1353\/6489\/files\/116674988709-0.jpg?v=1765837100","url":"https:\/\/www.blackstarassets.com\/products\/rosemount-3051t-pressure-transmitter-flowmeter-sensor-kit-w-1199-flange-nib","provider":"Blackstar Assets","version":"1.0","type":"link"}