Product opened for photos. Brand new in box.
Uninterruptible power supply with IQ technology for DIN rail mounting. Input: 120/230 V AC, output: 120/230 V AC/1 kVA. Provides information regarding the state of charge, remaining runtime, and service life of the rechargeable battery module at any time, thereby increasing system availability.
Features
- Can be switched in parallel for redundancy and increased performance
- Startup from energy storage possible, even without mains input
- USB interface for connecting to industrial PCs, for example
- Pure sine curve in mains and battery operation
- Smooth transition due to online topology
Tech Specifications
Width | 290 mm |
Height | 130 mm |
Depth | 125 mm |
Degree of protection | IP20 |
Ambient temperature (operation) | -25 °C ... 60 °C (> 50 °C Derating: 2.5 %/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C (with charged energy storage device) |
Max. permissible relative humidity (operation) | = 95 % |
Climatic class | 3K3 (EN 60721) |
Degree of pollution | 2 |
Installation height | = 3000 m (> 2000 m, observe derating) |
Nominal input voltage | 100 V AC -10 % / +20 % |
Nominal input voltage | 110 V AC -10 % / +20 % |
Nominal input voltage | 120 V AC -10 % / +20 % |
Nominal input voltage | 130 V AC -10 % / +20 % |
Nominal input voltage | 200 V AC -20 % / +20 % |
Nominal input voltage | 210 V AC -20 % / +20 % |
Nominal input voltage | 220 V AC -20 % / +20 % |
Nominal input voltage | 230 V AC -20 % / +15 % |
Nominal input voltage | 240 V AC -20 % / +10 % |
Input voltage range | 90 V AC ... 264 V AC |
AC frequency range | 45 Hz ... 65 Hz |
Buffer period | 1 h (38 AH) |
Permissible backup fuse | B16 230 V AC |
Power factor (cos phi) | 0.9 |
Nominal output voltage | 100 V AC |
Nominal output voltage | 110 V AC |
Nominal output voltage | 120 V AC |
Nominal output voltage | 130 V AC |
Nominal output voltage | 200 V AC |
Nominal output voltage | 210 V AC |
Nominal output voltage | 220 V AC |
Nominal output voltage | 230 V AC |
Nominal output voltage | 240 V AC |
Nominal output current (IN) | 7.8 A (100 V AC) |
Nominal output current (IN) | 8.1 A (110 V AC) |
Nominal output current (IN) | 8.3 A (120 V AC) |
Nominal output current (IN) | 7.7 A (130 V AC) |
Nominal output current (IN) | 5 A (200 V AC) |
Nominal output current (IN) | 4.8 A (210 V AC) |
Nominal output current (IN) | 4.5 A (220 V AC) |
Nominal output current (IN) | 4.3 A (230 V AC) |
Nominal output current (IN) | 4.2 A (240 V AC) |
POWER BOOST (IBoost) | 13 A (120 V AC) |
POWER BOOST (IBoost) | 7 A (230 V AC) |
Derating | > 50 °C ... 60 °C (2.5%/K) |
Connection in parallel | Yes, 2 |
Connection in series | No |
Maximum power dissipation in no-load condition | typ. 17 W (120 V AC) |
Maximum power dissipation in no-load condition | typ. 25 W (230 V AC) |
Net weight | 5 kg |
Efficiency | > 92 % (120 V AC) |
Efficiency | > 94 % (230 V AC) |
Protection class | I |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | 217546 h (230 V AC, at 40 °C) |
Connection Method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Connection Method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Connection Method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 30 |
Conductor cross section AWG max. | 12 |
Stripping length | 8 mm |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise immunity | Noise immunity according to EN 62040-2-2006 |
Standards/regulations | EN 61000-4-2 |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-6 |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V |
Conducted noise emission | EN 62040-02 (Class C2) |
Standards/regulations | EN 61000-4-8 |
Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
UL approvals | UL/C-UL Recognized UL 1778 |
Shock | 15g in all directions (EN 60068-2-27) |
Vibration (operation) | 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) |
Overvoltage category (EN 60950-1) | II |
REACh SVHC | Lead 7439-92-1 |
Discharge in air | 8 kV (Test Level 3) |
Input | 2 kV (Test Level 3 - asymmetrical) |
Output | 2 kV (Test Level 3 - asymmetrical) |
Signal | 2 kV (Test Level 3 - asymmetrical) |
Signal | 1 kV (Test Level 2 - asymmetrical) |
Frequency | 50 Hz |
Frequency | 60 Hz |
Criterion A | Normal operating behavior within the specified limits. |
Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
Installation distance right/left | 5 mm / 5 mm |
Installation distance top/bottom | 50 mm / 50 mm |
Harmonic currents | EN 61000-3-2 (Class A) |
Flicker | EN 61000-3-3 |